Key Features
Smart Electric Power Meter Single Phase 5-60Amp
Measurement of voltage, bidirectional current, active power, reactive power, apparent power, power factor, frequency, active energy, reactive energy.
Multi-rate energy statistics, up to 8 time slots per day, 4 tariffs.
Rated current 5 - 60A.
1 passive optical coupler collector active pulse outputs.
Wi-Fi communication,
LCD display a variety of power parameters and information.
Built-in clock and maintenance-free battery, permanently data saving after power off.
Large-capacity magnetic retention relay, load on-off control.
Data Sheet
- Model: JTSM1P-01
Wi-Fi Smart Electric Power Meter Single Phase 5-60Amp
JTSM1P-01
Wifi electric smart power meters are single phase / three-phase electricity meter with smart management system, it is a Wi-Fi enable electric meter with high accuracy up to Class 0.5S, easy to install with din rail mounting. It can measure the voltage, current, power, power factor, frequency with high reliability, fully comply to the international standard IEC62053/IEC62055-41/IEC62056-21. DIN rail smart energy meter is designed with advanced microprocessor and digital signal processing technology. It integrates comprehensive Single / three phase power measurement, display, energy accumulation, and network communication. It has strong anti-interference ability and can still work stably in situations with severe electromagnetic interference.
Applications:
Energy efficiency management system.
Internal energy consumption statistical analysis and charging statistics
Energy metering, automatic meter reading system.
Intelligent distribution management system.
Power consumption Monitoring System
Specifications | |
Altitude | No more than 4000m |
Clock accuracy | <0.5S/D |
Dimension | 108*66*75mm |
Electrostatic discharge immunity | IEC61000-4-2,Level4 |
Frequency | ±0.02Hz(0.01Hz) |
Frequency range | 45-65Hz |
Insulation resistance | >50MΩ |
Electrical Properties | |
Active energy | ±0.5%(0.1kWh) |
Active power | ±0.5%(0.1W) |
Current | ±0.2%(0.01A) |
Electrical fast burst immunity | IEC61000-4-4,Level4 |
Impact voltage | 5kV (Peak),1.2/50us |
Overall power consumption | <5VA |
Power factor | ±0.5%(0.001) |
Power frequency magnetic field immunity | IEC61000-4-8,Level4 |
Power frequency withstand voltage | AC2kV/min~1mA Input-output-power source |
Rated current | 5/10/20/60 A |
Rated voltage | AC 110V/220/230/240 V |
Reactive energy | ±2.0%(0.1kvarh) |
Reactive power | ±2.0%(0.1kvar) |
Starting current | 0.2%Ib |
Surge (impact) immunity | IEC61000-4-5,Level4 |
Voltage | ±0.2%(0.01V) |
Standard & Classifications | |
Protocol | Modbus-RTU |
Ambient Properties | |
IP class | IP51 |
Operating temperature | -25C to +55C |
Relative humidity | 5% - 95% No condensation |
Storage temperature | -30C to +75C |